|
Procedure for Producing Atomodine |
|
EQUIPMENT AND MATERIALS
1. 5
or 10 GALLON GLASS OR CERAMIC CONTAINER OR POT
2. 1
NICKEL ROD ½ INCH DIAMETER APPROXIMATE LENGTH 12 INCHES
3. 1
COPPER ROD ½ INCH DIAMETER APPROXIMATE LENGTH 12 INCHES
4. PLEXIGLASS
SUPPORT PLATFORM OR COVER , 0.20 “ THICKNESS RECOMMENDED THIS
PROVIDES A STRUCTURE FOR SUPPORTING RODS AND FLASK
a. THIS
PLEXIGLASS IS USED TO COVER CONTAINER & HOLD RODS IN PLACE
b. SUPPORT
COPPER AND NICKLE RODS BY DRILLING ½ “ HOLE ON EITHER SIDE OF WHERE
FLASK WILL BE HELD IN PLACE.
c. PROVIDE
OPENING TO PLACE FLASK CONTAINING IODINE INTO ELECTRICAL FLOW
BETWEEN RODS, DOWN INTO ELECTROLYTIC SOLUTION
d. A
SUPPORT DEVICE (CLAMP ON HEAVY DEVICE) TO HOLD A FLASK WITH A GLASS
STOPPER, BETWEEN THE RODS, WITH THE IODINE SOLUTION DOWN BENEATH THE
SURFACE OF THE ELECTROLYTIC LIQUID.
5. A
LONG NECK GLASS FLASK, WITH GLASS STOPPER FOR HOLDING TINCTURE OF
IODINE SOLUTION, STOPPER ATTACHED WITH WIRE, ALLOWS HEATED GAS IN
BOTTLE TO ESCAPE BUT KEEPS STOPPER FROM BEING SHOT OFF FLASK.
6. BATTERY
SOLUTION FOR FIVE GALLON CONTAINER (DOUBLE FOR 10)
a.
THREE
(3) GALLONS DISTILLED WATER
b.
TWO (2)
POUNDS COPPER SULFATE
c.
ONE AND
ONE HALF (1 & 1/2) OUNCE SULFURIC ACID CP
d. ONE (1)
OUNCE GRANULATED ZINC
e. ADDED
IN THIS ORDER AND ALLOWED TO SIT 24 HOURS IF POSSIBLE
7. AMP
METER
FOR MONITORING 110 VOLTS AT 30 AMPS OF RESISTANCE FOR 15 MINUTES.
CONTROL AMPERAGE BY EXTENDING RODS DEEPER INTO LIQUID
8. VOLUME
OF TINCTURE OF IODINE TO BE ELEVATED TO NASCENT STATE SHOULD NOT
EXCEED 1 OUNCE OF TINCTURE OF IODINE FOR ONE GALLON OF ELECTROLYTIC
SOLUTION IN CONTAINER OR POT, 3 OUNCES IN 5 GALLON POT WITH 3 GALLONS
OF DISTILLED WATER
9. TINCTURE
OF IODINE SHOULD BE 1 % IODINE BY WEIGHT 99 % ALCOHOL (4.5 GRAMS OF
CRYSTAL IODINE [1/100 OF A POUND]FOR 1 POUND OF EYTHL ALCOHOL)
10. TEMPERATURE
OF LIQUID SHOULD NOT BE ALLOWED TO BECOME TO HOT
11. HOOKING
THREE 10 GALLON CONTAINERS IN SERIES HELPS KEEP TEMPERATURE DOWN,
THE MORE LIQUID THE LONGER TO HEAT.
12. ELECTROLYTIC
BATH SHOULD BE REPLACED WHEN IT NO LONGER HAS A CHARGE. WITH A/C
CONNECTION REMOVED A CHARGE BETWEEN RODS SHOULD SHOW ON VOLT METER
OR REPLACE EVERY MONTH. IF MUCH CHARGING OF NASCENT IODINE THEN
MAYBE EVERY WEEK.
IODINE
SHOULD BE TRANSFERRED TO A DARK COLORED CONTAINER FOR STORAGE AND
KEPT FROM HEAT.
WHEN
NASCENT IODINE IS DILUTED IT STARTS TO REACT IN NASCENT STATE.
NASCENT IODINE PREPARED THIS WAY APPEARS TO BE ACTIVE IN THE BODY
FOR TWO TO THREE HOURS. HEALTH CARE PROVIDER SHOULD BE CONSULTED
ABOUT USE. SMALL DOSES MORE OFTEN ARE BETTER THAN A SINGLE LARGE
DOSE. A CYCLIC USE WITH DAYS OF REST FROM USE IS RECOMMENDED.
SETTING
UP A 110 VOLT A/C CURRENT WITH 30 AMP BREAKERS ELECTRICAL
CONNECTIONS REQUIRES A PROFESSIONAL ELECTRICIAN AND IS DANGEROUS TO
WORK WITH.
CARE
SHOULD BE TAKEN IN SETTING THIS UP.
 |